by Sealbond Chemical Industries | Oct 5, 2016 | Structural Epoxies
SEALBOND 385-UE
UNDERWATER EPOXY
SEALBOND EPOXY UNDERWATER (385-UE) is a 100% Epoxy-Amine type curing agent especially formulated for use to cure at high humidity, low temperature (down to 5°C) and underwater. It has excellent chemical resistance and low water miscibility. It renders excellent adhesion and bonding capabilities designed for the all around remedy of structural concrete defects and flaws through pressurized injection and grouting and for other marine applications. It may be applied even on damp surfaces or even during cold conditions.
USES
- Bonding non-slip materials to hardened concrete.
- Pressure injection repairs of cracked concrete walls, floors, beams, and other structures for above or underwater applications.
- Forms an epoxy mortar when mixed with graded fine aggregates for high strength grouting repair of concrete surface/structures.
APPLICATION
PRESSURE INJECTION: Blow compressed air along the crack lines to completely clean, dry and remove dirt and other loose contaminating materials. Provide temporary seal on crack surface except entry and exit ports. Inject Sealbond 385-UE starting at the lowest entry port up to the proceeding ports until the voids are completely filled.
EPOXY GROUTING V-CUT SYSTEM: V-cut all cracks for repair. Blow compressed air along the crack lines to completely clean, dry and remove dirt and other loose contaminating materials. Apply by brush pure Sealbond Epoxy 385-UE to serve as primer then apply Sealbond Epoxy 385-UE mixed with silica sand or patching compound on v-cut surface.
EPOXY GROUTING ON CONCRETE HONEYCOMB: Chip off loose concrete. Remove dust, dirt and other loose contaminating materials. Install formworks on honeycomb providing for a small opening on the upper portion. Pour Sealbond Epoxy 385-UE mixed with silica sand. Remove formworks upon curing of epoxy grout.
MIXING AND CLEANING
MIXING: Mix thoroughly by volume 2 parts of resin to 1 part of hardener for 3 to 4 minutes. Any changes from the recommended proportion will affect its quality. Scrape the bottoms, sides and corners of the container to ensure complete and full blending. Prepare only enough quantities that can be used within the pot-life period. Do not delay application.
CLEAN-UP: Pressure injection tools and other equipment maybe cleaned with Sealbond Epoxy Reducer while the mixture has not yet hardened. Wash off hands with detergent and warm water.
CAUTION: Avoid contact with eyes and skin and avoid breathing its vapor. This product may cause severe skin irritation after prolonged or repeated exposure. Keep containers tightly closed and store in a cool dry place.
by Sealbond Chemical Industries | Oct 5, 2016 | Structural Epoxies
SEALBOND 218-P
PRESSURE INJECTION EPOXY
SEALBOND PRESSURE INJECTION EPOXY (218P) is a two component adhesive system composed of 100% solids Epoxy that contains polyamide curing agent ensuring a tough and durable bond resistant to chemicals and corrosion. This unique low viscosity adhesive is primarily designed for the all around remedy of structural concrete defects and flaws particularly the repair of cracks by epoxy injection. Aside from sealing cracks and crevices and filling voids, it can also be combined with fine aggregates or silica sand to result in an Epoxy Mortar for high strength grouting.
APPLICATION
PRESSURE INJECTION: Blow compressed air along the crack lines to completely clean, dry and remove dirt and other loose contaminating materials. Provide temporary seal on crack surface except entry and exit ports. Inject Sealbond 218-P epoxy injection starting at the lowest entry port up to the proceeding ports until the voids are completely filled.
EPOXY GROUTING V-CUT SYSTEM: V-cut all cracks for repair. Blow compressed air along the crack lines to completely clean, dry and remove dirt and other loose contaminating materials. Apply by brush pure Sealbond Epoxy 218-P to serve as primer then apply Sealbond Epoxy 218-P mixed with silica sand or patching compound on v-cut surface.
EPOXY GROUTING ON CONCRETE HONEYCOMB:
Chip off loose concrete. Remove dust, dirt and other loose contaminating materials. Install formworks on honeycomb providing for a small opening on the upper portion. Pour Sealbond Epoxy 218-P mixed with silica sand. Remove formworks upon curing of epoxy grout.
MIXING AND CLEANING
MIXING: Mix thoroughly by volume 2 parts of resin to 1 part of hardener for 3 to 4 minutes. Any changes from the recommended proportion will affect its quality. Scrape the bottoms, sides and corners of the container to ensure complete and full blending. Prepare only enough quantities that can be used within the pot-life period. Do not delay application.
CLEAN-UP: Pressure injection tools and other equipment maybe cleaned with Sealbond Epoxy Reducer while the mixture has not yet hardened. Wash off hands with detergent and warm water.
CAUTION: Avoid contact with eyes and skin and avoid breathing its vapor. This product may cause severe skin irritation after prolonged or repeated exposure. Keep containers tightly closed and store in a cool dry place.
by Sealbond Chemical Industries | Oct 5, 2016 | Structural Epoxies
SEALBOND 215-B
CONCRETE EPOXY ADHESIVE
SEALBOND CONCRETE EPOXY ADHESIVE (215-B) is a two component adhesive system specially formulated for structural concrete application and bonding of old to new concrete. It has a low to medium viscosity. When compounded, the admixture produces a strong bond with minimum shrinkage and flexibility properties. It contains a special polymeric curing agent that provides the film with a high degree of toughness, adhesion and chemical corrosion resistance.
APPLICATION
SEALBOND 215-B is highly recommended for the following:
- Bonding new to old concrete
- Repair of cracked concrete structure including earthquake damages
- Sealing concrete pavement and structure against intrusion of water
- dowelling
- Bonding non-slip aggregates on concrete surfaces
- Securing overlays on concrete surfaces
- General purpose adhesive
SURFACES PREPARATION AND APPLICATION PROCEDURE
- Clean surface from debris, oil, grease, dirt and other foreign materials either by mechanical method or chemical process.
- Mix 2 parts by volume of resin base to 1 part by volume of hardener. Mix only enough quantities that can be used within the pot-life of the mixture.
- Apply SEALBOND EPOXY 215-B at the rate of 6 to 8 sq. meters per gallon depending on the thickness of deposit or porosity of the substrate.
- Pour fresh concrete while SEALBOND EPOXY 215-B is still wet or tacky.
- Use brush with stiff bristles to fill up concrete voids and concrete crevices with Epoxy industrial Adhesive.
- Clean up. All tools and equipment must be cleaned immediately after application. Use Sealbond Epoxy Reducer to remove excess resin and hardener.
PRECAUTION
Wear rubber or plastic gloves to avoid contact with skin. Use soap and water to remove the mixture from hands. Do not use strong solvents to remove mixture from skin.
by Sealbond Chemical Industries | Oct 5, 2016 | Specialty Products
SKIMPLAST
SKIMCOAT ULTRA THIN PLASTERING
‘BEST FOR CONCRETE WALLS AND CEILING’
SKIMPLAST SKIMCOAT ULTRA THIN PLASTERING is a dry powder containing binders and mineral fillers which need only the addition of water to produce a high strength cement plaster for ceilings and walls that can be applied very thinly up to 1mm thick without cracking or flaking. It has excellent adhesion and non-sag property specially designed to correct rough and uneven concrete surfaces to produce a good base for paint application.
CUSTOMER BENEFITS
SKIMPLAST offers the following advantages:
- Can be applied very thinly up to 1mm without cracking or flaking saving bigger cost on plastering works.
- Smooth surface can be achieved thru manual sanding to save on paint consumption.
- A non toxic material resistant to ultraviolet rays and to wind-driven rain.
RECOMMENDED FOR:
- Correction of uneven concrete surfaces such as: interior and exterior walls and ceilings, formed concrete walls and pre-cast panels.
- Patching and repair of cracks, pinholes and dent gaps.
- Serves as filler to honeycomb of concrete slab, ceiling, columns and beams.
SURFACE PREPARATION
Surfaces must be structurally sound and thoroughly clean. Remove loose materials, dust, dirt, oil, laitance and other contaminants. All surfaces must be damped down with clean water just prior to application of SKIMPLAST.
MIXING AND APPLICATION
Mix 1 part of SKIMPLAST to 0.3 part of clean water by volume in a suitable plastic container until a lump free consistency is attained. For best result, let the mixture stand for 10-15 minutes and stir again. Refrain from adding more water even if the mixture is already beginning to set, any changes from the recommended mixing ratio will affect the properties of the product. Using a steel trowel or putty knife, apply SKIMPLAST evenly to the desired thickness. Additional coats can be applied as needed. Allow an undercoating interval of at least 20 minutes. Sanding may be necessary to obtain a higher degree of smoothness. Allow plastered wall to cure for at least 3-5 days. Wash surface with wet sponge and let dry before applying paint as final coat.
by Sealbond Chemical Industries | Oct 5, 2016 | Specialty Products
SKIMPLAST LP670
SKIMCOAT LIQUID PASTE
‘BEST FOR CONCRETE WALLS AND CEILING’
SKIMPLAST LIQUID PASTE LP670 is a ready to use rendering paste for ceilings, exterior and interior walls. It’s a ready to use product formula for repairing surface defects in concrete or render. A smooth surface is attained by eliminating imperfections such as grooves, seams and fine cracks.
CUSTOMER BENEFITS
SKIMPLAST LIQUID PASTE offers the following advantages:
- Can be applied thinly up to 0.5mm to 4mm without flaking saving bigger cost on plastering works.
- A non toxic material resistant to ultraviolet rays and to wind-driven rain.
- No water needed
- Excellent trowelability for applicators
- Excellent white smooth finish
RECOMMENDED FOR:
- Correction of uneven concrete surfaces such as: interior and exterior walls and ceilings, formed concrete walls and pre-cast panels.
- Patching and repair of cracks, pinholes and dent gaps.
- Serves as filler to honeycomb of concrete slab, ceiling, columns and beams.
SURFACE PREPARATION
Surfaces must be structurally sound and thoroughly clean. Remove loose materials, dust, dirt, oil, laitance and other contaminants. All surfaces must be damped down with clean water just prior to application of SKIMPLAST LIQUID PASTE LP670.
APPLICATION
- Apply small quantities of SKIMPLAST Liquid Paste with stainless steel float.
- Two separate coats must be applied for a successful resurfacing (First layer as primer)
- Allow 2 hours at normal temperature between coats. Pre-covering curing time 24-48 hours.